On 26 October 2026 a cybersecurity event at the University of New Mexico Health Sciences Center led UNM Health to divert ambulance traffic to other area health systems for about two hours. It also suspended outpatient surgeries and appointments for the rest of the day. UNM said critical systems were restored in phases from that afternoon, and clinics resumed scheduled care on 27 October.
24 October 2026Lexington, Massachusetts, United StatesFell to tier 3: analog fallbackPower
On the night of 24 October 2026 more than 100 residents were evacuated from a nursing and rehabilitation centre in Lexington, Massachusetts, after electrical problems that had recurred over several days. Officials ordered the building de-energised because other building systems, including sewage, were tied into the electrical system.
CISA disclosed six vulnerabilities in the dcm4chee-arc-light medical imaging archive. According to the advisory, they could let an attacker delete stored images, file forged studies, reassign studies to another patient or cause a denial of service. CISA reported no known exploitation and recommends updating to version 5.35.2 or later.
On 13 October 2026 a disruption across Singapore's three public healthcare clusters (NHG Health, NUHS and SingHealth) affected appointment booking, visitor registration, medication dispensing and billing for about nine and a half hours. In its reply to parliamentary questions, the Ministry of Health said the cause was a required security update to a shared Domain Name System (DNS) service. Synapxe had contracted a service provider to do the update, and it was not done before a scheduled global change.
PathConnectivity & data → Human handoff
On 8 October 2026 a network outage took some computers and digital devices offline across Mass General Brigham. Its hospitals moved to downtime procedures, including paper forms, and some elective outpatient procedures did not go ahead. MGB said the outage was not linked to a cyberattack; the cause had not been stated.
A fault in the Northern Territory government's core IT network disrupted every government agency for most of 8 October 2026. Hospitals including Royal Darwin Hospital started continuity plans, and officials said clinicians faced delays and could not reach some systems.
During a national grid outage in Cuba in September 2026, the Fe del Valle Ramos maternity hospital in Manzanillo said its electrical microsystem failed at the same time as its generator. The hospital said the situation was resolved in a short period and that no complications among pregnant women, postpartum women or newborns were recorded.
Under review
17 September 2026United States (US nationwide including Puerto Rico; models also sold in Japan)Devices
React Health (Ventec Life Systems) warned that the internal flow transducer cable connector in VOCSN ventilators can unseat and cause reboots and recurring System Fault 10 alarms, which could interrupt ventilation. FDA called it a potentially high-risk device issue, and the VOCSN+Pro entry is classified Class I.
FDA issued an Early Alert in October 2026 after Philips reported that its Lumify ultrasound app may stop recognising a registered transducer and block scanning until re-registration, which requires Wi-Fi or cellular access. As of 29 September 2026 Philips had reported eight serious injuries and four deaths associated with the issue.
PathConnectivity & data → Devices
On 14 August 2026 four joint-replacement patients at Ascension Saint Thomas Midtown received potassium phosphate instead of the anaesthetic mepivacaine. NewsChannel 9 reported that a state survey report found the pharmacy system let technicians override barcode scanning, and that the pharmacist's final check also missed the wrong drug.
Boston Scientific notified clinics that its LATITUDE Clarity remote-monitoring server can delay AF Burden alerts from LUX-Dx insertable cardiac monitors until the next full device interrogation when a non-default threshold is set. The implanted monitors keep detecting and transmitting data; one complaint and no injuries were reported.
July 2026United States, Japan, Germany and other markets (per Nova)No outage: wrong outputDevices
Nova Biomedical's StatStrip Gen 2.0 hospital glucose meters can keep a previously scanned patient or quality-control barcode on screen. If the operator accepts it, the glucose result is filed under the wrong patient. FDA classified the recall as Class I, and as of 5 October 2026 Nova had reported one serious injury and no deaths.
In a nationwide online survey of 1,003 UK GPs in August 2025, 141 used ambient AI scribes. Of these users, 32% reported errors often or always, and 14% reported errors with significant-to-critical implications. All figures are self-reported.
A BMC Psychiatry case report describes a man in his 30s with substance-induced manic psychosis whose ChatGPT conversations, according to the authors, affirmed his perceived 'spiritual awakening' and discouraged his prescribed antipsychotic. His inpatient care plan restricted AI chatbot use; the authors state that any contribution of the chatbot to his illness cannot be determined.
Update pending
Ontario's Auditor General found every AI scribe on the province's approved vendor list had fabricated, wrong or missing content in procurement tests, including 12 of 20 recording the wrong drug.
A pharmacy chain's AI voice and text assistant for refills mispronounced medications, ordered wrong dosages and duplicate refills, and gave callers no keypad alternative; after hundreds of complaints the chain pulled it back.
Under review
January 2026Arizona, New Jersey, Ohio, Oklahoma, Texas and Washington, United StatesFell to tier 1: assisted operationModels & agents Human handoff
CMS's WISeR model, in which technology vendors use AI and machine learning to review prior-authorization requests in traditional Medicare, launched in January 2026 in six states. CMS records obtained by EFF and reporting by KFF Health News describe long delays, an erroneous denial and a vendor that said it would auto-approve requests until its system was fully functional.
Update pending