Endoscopists detect fewer adenomas without AI after AI is introduced
After AI polyp detection was introduced, the adenoma detection rate of standard non-AI colonoscopy fell from 28.4% to 22.4%.
how automated healthcare fails, how you'd know, and what to do at each tier — every claim sourced, reviewed continuously
In a randomized simulation trial at UCSF, 77 pharmacists and pharmacy trainees verified medication orders with and without GPT-4o recommendations. Assistance raised overall accuracy, but participants accepted 73.9% of incorrect AI recommendations, and their accuracy fell to 26.1% when the AI was wrong.
TierSimulation study; no tier applies. How tiers are assigned.
Surdilla and colleagues, writing in the American Journal of Health-System Pharmacy, randomly assigned each of 10 clinical scenario questions to an unassisted arm or an AI-assisted arm. In the assisted arm, OpenAI's GPT-4o gave a binary 'verify' or 'not verify' recommendation with an explanation. Participants were 29 students, 14 PGY1 residents, 11 PGY2 residents and 23 pharmacists. AI assistance was associated with higher overall accuracy (adjusted odds ratio 1.58; 95% CI 1.16-2.15), with the greatest benefit among students and the least among PGY2 residents. Performance depended on whether the AI was right. With correct recommendations, user accuracy was 80.2%; with incorrect ones, it fell to 26.1%. Participants accepted 80.2% of correct recommendations and 73.9% of incorrect ones. When users disagreed with the AI, their accuracy was 21.7%, which the authors describe as participants being rarely successful when attempting to override the model. The authors conclude that AI should augment, not replace, pharmacist judgment, and that safe integration requires pharmacist-guided validation of model output and training focused on trust. These findings match the pattern described in an earlier systematic review of automation bias in clinical decision support, which found that over-reliance is shaped by trust, experience, workload and time pressure.[1,2]
none documented (simulation)
After AI polyp detection was introduced, the adenoma detection rate of standard non-AI colonoscopy fell from 28.4% to 22.4%.
In a controlled experiment, 27 radiologists' accuracy on mammograms fell sharply when a purported AI suggested an incorrect BI-RADS category.
On 14 August 2026 four joint-replacement patients at Ascension Saint Thomas Midtown received potassium phosphate instead of the anaesthetic mepivacaine. FOX 17 News, in a report published on NewsChannel 9's website, said a state survey report found that the pharmacy system let technicians override barcode scanning and that the pharmacist's final check also missed the wrong drug. In November 2026 one patient sued the hospital.
Non-clinical analogue. The human operator meant to back up an automated driving system was looking at her phone; the NTSB cited automation complacency.
A 60-year-old ICU patient's monitor alarmed for rising heart rate and falling oxygen saturation; staff responded only after about an hour, when he had stopped breathing.
A patient on a cardiac monitor died after the monitor's crisis alarm had been left off; lower-level alarms sounded at the nurses' station but went unheeded.
Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.